| Client Information | XXXXXXXXXXXXX XXXXXXXXXXXXXX | | | | | Date of Inspection: August 3, 2008 | Time: 10:00 AM | Weather Conditions: Clear, Dry and Warm with very slight breeze. |
|
Property Address: XXXXXXXXXXX XXXXXXXXXXXXX |
| Attendance: Buyer Buyer's Agent Mary (Sister), "Radon Ron" |
|
Important Information | This report is solely for the benefit of the Client. Any person or party designated by the Client to receive information in this report shall be subject to the TERMS AND CONDITIONS contained herein. Such designation shall be provided in writing to the inspector. |
| | This inspection is not intended to address or include any geological conditions or site stability information. For information concerning these conditions, a geologist or soils engineer should be consulted. Any reference to grade is limited to only areas around the exterior of the exposed foundation or exterior walls. This inspection is visual in nature and does not attempt to determine drainage performance of the site or the condition of any underground piping, including municipal water and sewer service piping or septic systems. When decks and porches are built close to the ground where no viewing or access is possible, we cannot make accurate opinions. These areas as well as others that are too low to enter, or in some other manner not accessible, are excluded from the inspection and are not addressed in this report. We routinely recommend that inquiry be made with the seller about knowledge of conditions. |
| Driveway Type: Asphalt Condition: Satisfactory
Comments: Driveway shows some cracking - Not unusual. Seal coating can be applied every two to five years to prolong driveway life. |
| Steps To Building Stair Type: Concrete Landing: Concrete Railing: Yes Condition: Satisfactory |
| Sidewalks/Walkways Type: Concrete Condition: Satisfactory |
| General Grading/Drainage Condition: Satisfactory
Comments: Proper grading is the best way to prevent water leaks into basements. |
| Trees & Shrubs Condition: Satisfactory
Comments: Shrubs have proper clearance to foundation. |
| Out Buildings Condition: Needs Maintenance Out Building: Observed
Comments: This "Child's Play House" needs a general cleaning inside and out. At present, its use is general storage. Electrical outlets and lights were observed, however, no electrictal current was evident. Check with Owners if this building is controled by a switch in the Garage or other area. |
|
| | Our inspection of the Exterior grounds includes the surface drainage, grading, some fencing, gates, sidewalks, patios, driveways, and retaining walls adjacent to the structure. The inspection of the exterior of the building includes the cladding, trim, eaves, fascias, decks, porches, downspouts, railings, doors, windows and flashings. Areas hidden from view by finished walls or stored items cannot be judged and are not a part of this inspection. Minor cracks are typical in many foundations and most do not represent a structural problem. If major cracks present along with rotation, we routinely recommend further evaluation be made by a qualified professional structural engineer. The grading of the soil should allow for surface and roof water to flow away from the foundation. All concrete slabs experience some degree of cracking due to shrinkage in the drying process or minor settlement. All items listed are inspected for their proper function, poor installation, excessive wear and general state of repair. Where deck carpeting, stacked firewood, excessive vegetation, soil and other coverings are installed over decking and patio surfaces, the materials or their nature of construction and condition of the underneath these coverings cannot be determined. |
| Building Information Year Constructed: 1925 Type: Single
Comments: Building Information as listed with Realtor listing: "Sears" Home - Six Rooms and Bath. A Full basement was added to the original plans. A Family room was added to modernize the home to the present day. |
| Wall Covering Condition: Needs Maintenance Type: Wood
Problems: -The paint is peeling off the siding material.
Comments: Due to the age of the house, exterior painting (scraping, power wash and painting) should be scheduled within the next two years. Caulking should also be done around windows and vents (pipes, conduits, etc.). |
| Exterior Receptacles Condition: Needs Maintenance Type: Non-GFCI
Comments: Only two exterior receptacle were observed; located on the back wall - ground level, and one in the "roof garden". These outlets are not a GFCI's, but are protected by exterior boxes. The second box is not secured to the wall. |
| Gas Meter & Piping Condition: Satisfactory
Problems: *The pipes were not inspected for rust. *The location of the gas meter/piping was not inspected.
Comments: Outside gas connection has no turn-off. This is the pressure reducer only. The main turn-off and meter reading is in the basement. |
| Exterior Windows Condition: Satisfactory
Comments: New vinyl thermal pane windows were installed in Feb. 2007 according to the house listing. All windows have been observed to be properly installed. |
| Exterior Doors Condition: Satisfactory Type: Combination
Problems: *The doors were not inspected to see if there are interior doors functioning as exterior doors. *The doors were not inspected for difficulty when opening and closing. *The exterior doors were not inspected for problems with swinging over stairs. *The door was not inspected for rot at the sill. *The door was not inspected for cracked, broken, or delaminating sections.
Comments: The front screen door may need adjustments. |
| Foundation Condition: Satisfactory Type: Concrete
Comments: One small crack was observed. No water seepage was evident. |
| Downspouts Condition: Satisfactory
Comments: Gutters and downspouts appear to be satisfactory. Observations should be made during a rain day. Proper extensions have been added. |
| Eaves & Soffits Condition: Needs Maintenance
Problems: *The area was not inspected for sagging soffit panels. *The soffit ventilation was not inspected for water stains or holes. *The eave vent screens were not inspected for damage. *The gable louvers were not inspected for missing slats or debris. *The area was not inspected for problems with poor caulking.
Comments: Soffits and facia should be scrapped and painted along with the exterior walls. |
| Chimney(s) Condition: Needs Maintenance Type: Brick Location: North side
Comments: Tuck-pointing chimney as needed. This should be scheduled within the next 2 years. |
|
| | The inspection of the roof system includes a visual examination of the surface materials, connections, penetrations and roof drainage systems. We examine the roofing material for damage and deterioration. We examine the roof system for possible leaks, damage and conditions that suggest limited remaining service life. We may offer opinions concerning repair and/or replacement if warranted. Opinions stated herein concerning the roofing material are based on the general condition of the roof system as evidence by our visual inspection. These do not constitute a warranty that the roof is or will remain, free of leaks. All roofing systems require annual maintenance. Failure to perform routine maintenance will usually result in leaks and accelerated deterioration of the roof covering and flashings. When provided, our estimates of the roof's life expectancy are based on the assumption that the roof will be properly maintained during that period. The only way to determine whether a roof is absolutely watertight i s to observe it during a prolonged rainfall. Many times, this situation is not present during the inspection and we cannot confirm this condition. We suggest that an annual inspection of the Attic area be performed where accessible to identify if any leaks are evident. |
| Roof Style Type: Hip, Shed
Comments: Per listing information, the roof was replaced 10 years ago. The roof was observed to be a tear-off and one ply asphalt shingles. Roof was observed best from the second floor landing. |
| Roof Covering Type: Asphalt Layers: 1 Layer Approximate Age: 10 years Condition: Satisfactory |
| Roof Leaks Leaks: None Observed Viewed: Ground |
| Gutters & Downspouts Type: Galvanized Condition: Satisfactory Extensions: Has Extensions
Comments: Gutters on second floor are attached by hanging brackets. These brackets appear to properly installed. |
| Vents / Protrusions Condition: Satisfactory |
|
| | Our Inspection of the plumbing system includes a visual examination of the exposed portions of the domestic water supply, drain waste, vent, gas lines, faucets, fixtures, valves, drains, traps, exposed pipes and fittings. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. The hidden nature of piping prevents inspection of every pipe and joint connection, especially in walls, floors and ceiling voids. A sewer lateral test is necessary to determine the condition of the underground sewer lines. This type of test is beyond the scope of this inspection. Our review of the plumbing system does not include landscape irrigation systems, water wells, on site and/or private water supply systems, off site community water supply systems, or private (septic) waste disposal systems unless specifically noted. A qualified specialist prior to the closing of escrow can perform review of these systems. Our inspection of the water heater includes a visual examination of the accessible portions of the tank, gas, electrical and/or water connections, venting and safety valves. These items are examined for proper function, excessive or unusual wear, leakage and general state of repair. |
| Fuel Service Condition: Satisfactory Type: Gas Meter Meter Location: Basement furnace room Shutoff Valve Location: Shutoff on meter
Comments: This component is functioning properly. |
| Water Entrance Service: Public Type: Lead Main Shutoff Valve Location: Basement Furnace room under shelf Size: 3/4"
Comments: Water pressure was tested to be 48 psi. which is adequate. The street valve could not be located. |
| Waste Condition: Satisfactory Type: Public Pipes: Plastic, Cast Iron |
| Fixtures Condition: Satisfactory |
| Water Heater Condition: Satisfactory Fuel Type: Gas Location: Next to furnace Capacity: 40 Extension: Relief Valve: Present Seismic Restraint: Gas Shutoff: Present Venting (Air Supply): Not Applicable
Problems: -There is improperly installed overflow piping.
Comments: Per listing information, water heater was replaced 3 years ago. |
| Pipes Condition: Satisfactory Material: Copper, Galvanized Flow Rate: Satisfactory |
| Drains Condition: Satisfactory Type: Plastic, Cast Iron
Comments: Main clean-out is next to water heater. Main drain is in-ground. |
| Vent Pipes Condition: Satisfactory Type: Cast Iron |
|
Electrical Systems & Components |
| | Our examination of the electrical system includes a visual examination of the exposed and accessible branch circuits, wiring, service panel, over current protection devices, lighting fixtures, switches, and receptacles. Service equipment, proper grounding, wiring methods and bonding are focal points. We inspect for adverse conditions such as lack of grounding and bonding, over-fusing, exposed wiring, open-air wire splices, reverse polarity and defective GFCI's. The hidden nature of the electrical wiring prevents inspection of every length of wire or their connections. Telephone, video, cable, audio, security systems and other low voltage systems were not included in this inspection unless specifically noted. We recommend you have the seller or a specialist demonstrate the serviceability or locations of these systems to you if necessary. Any electrical repairs attempted by anyone other than a licensed electrician should be approached with caution. The power to the entire house should be turned off prior to beginning any repair efforts, no matter how trivial the repair may seem. Aluminum wiring requires periodic inspection and maintenance by a licensed electrician. Operation of time clock motors is not verified. Inoperative light fixtures often lack bulbs or have dead bulbs installed. Light bulbs are not changed during the inspection, due to time constraints. Smoke Alarms should be installed within 15 feet of all Bedroom doors and in Bedrooms. These units should be tested monthly. |
| Service Line Entrance Condition: Satisfactory Type: Overhead Conductor: Aluminum Location: North side Wiring: Volts: 240 - 120v Capacity: 100 |
| Main Panel Condition: Satisfactory Volts: 240-120v Capacity: 100A Type of Overload Protection: Circuit Breakers Bonding: Bonded Grounding: Grounded Location: Basement West wall
Comments: Panel is well labeled. All wiring is 12AWG with 15 Amp breakers which is more than proper.. |
| Outlets, Fixtures, & Switches Number Tested: Representative Number Method of Testing: Receptacle tester Condition: Needs Maintenance Outlet Testing: Reverse Polarity: Yes Non-GFCI: Yes Ungrounded: No Voltage Drop: No
Problems: -There are outlets spaced too far apart.
Comments: Two bedrooms have only 2 outlets. The master bedroom has more than enough outlets. Two are still two prong, and one has reverse polarity. (Other rooms will be listed separatly.) |
| Smoke Detectors Condition: Not observed. Smoke Detectors: Not Tested
Comments: If no smoke alarms are present, New alarms should be installed on every level.
New alarms should be installed every 10 years. |
|
| | Our inspection of the Attic includes a visual examination of the roof framing, plumbing, electrical, and mechanical systems. There are often heating ducts, bathroom vent ducts, electrical wiring, chimneys and appliance vents in the Attic. We examined these systems and components for proper function, unusual wear and general state of repair, leakage, venting and unusual or improper improvements. When low clearances and deep insulation prohibits walking in an unfinished Attic, inspection will be from the access opening only. Vaulted ceilings cannot be inspected. |
| Attic Access Access Type: Pull Down Attic Access Location: Top floor hallway |
| Attic Ventilation Condition: Satisfactory Type: Roof Vents Fan Type: Attic Fan, Whole House Fan
Problems: -The fan does not operate properly.
Comments: The roof fan located in the attic did not operate. Possible new fan or themastat needed.
Whole house fan is switch operated. |
| Roof Frame Condition: Satisfactory Type: Rafter Framing |
| Vent Pipes & Flashing Condition: Satisfactory Leaks Observed: No Leaks |
| Ceiling Frame Condition: Satisfactory Type of Framing: Joist Framing
Problems: *The ceiling frame was not inspected for splitting or bowing.
Comments: The ceiling frame is covered by plywood which makes the attic available for general storage. |
| Moisture & Mildew Condition: Satisfactory Type: None |
| Attic Insulation Condition: Satisfactory Type: Batts, Combination Location: In Floor Average Depth (Inches): 8
Problems: *The area was not inspected for improperly installed vapor barriers.
Comments: Insulation is covered by floor boards. Additional insulation would be impractible. All floor boards would have to be removed and no storage would be possible. |
| Attic Sheathing Observed: Observed Condition: Satisfactory |
|
| | Our inspection of the Interior includes a visual inspection of the readily accessible portions of the walls, ceilings, floors, doors, cabinetry, countertops, steps, stairways, balconies and railings. Please note that a representative sample of the accessible windows and electrical receptacles are inspected. These features are examined for proper function, excessive wear and general state of repair. In some cases, all or portions of these components may not be visible because of furnishings and personal items. In these cases some of the items may not be inspected. The condition of walls behind wall coverings, paneling and furnishings cannot be judged. Only the general condition of visible portions of floors is included in this inspection. As a general rule, cosmetic deficiencies are considered normal wear and tear and are not reported. Determining the source of odors or like conditions is not a part of this inspection. Floor covering damage or stains may be hidden by furniture. The condition of floors unde rlying floor coverings is not inspected. Determining the condition of insulated glass windows is not always possible due to temperature, weather and lighting conditions. Check with owners for further information. All fireplaces should be cleaned and inspected on a regular basis to make sure that no cracks have developed. Large fires in the firebox can overheat the firebox and flue liners, sometimes resulting in internal damage. |
| General Information Number of Bathrooms: 2 Number of Bedrooms: 2 |
| Floors Condition: Satisfactory Type of floor: Hardwood, Carpet, Vinyl
Comments: he main floor shows signs of squeaking which is normal in older homes. No floor bouncy or inadequate support was observed.
The upper floor is hardwood flooring throughout except in the bathroom which is vinyl flooring. |
| Walls Condition: Satisfactory Type: Drywall
Comments: The general appearance and condition of the walls is satisfactory. |
| Ceilings Condition: Satisfactory Type: Drywall
Comments: The only evidence of past water damage and ceiling cracks is in the master bedroom. However, these signs are not major. Minor spackaling before painting will correct this fault. |
| Entry Doors Condition: Satisfactory Material: Wood Insulation: Insulated |
| Interior Doors (door # 1) Location: Condition: Satisfactory
Comments: Minor adjustments and/or planing may be required for doors to function properly. |
| Stairs / Railings Condition: Satisfactory
Problems: -The stairs are missing a railing. -The stairway is not sufficiently lighted.
Comments: Hand rails may be added for safety on all stairs.
Stairs leading to second floor may be inadequate. Lights are located at the bottom and the top hallway. An additional light may be needed. |
| Windows Condition: Satisfactory Type: Double Hung Material: Vinyl Glass: Insulated Glass Storm Windows: No |
| Moisture and Mildew Condition: Satisfactory Degree of Damage: None |
|
| | Our inspection of the bathrooms included a visual examination of the readily accessible portions of the floors, walls, ceilings, cabinets, countertops and plumbing fixtures. Bathrooms are inspected for water drainage, damage, deterioration to floor and walls, proper function of components, active leakage, unusual wear and general state of repair. Bathroom fixtures are run simultaneously to check for adequate water flow and pressure. Fixtures are tested using normal operating controls. Vent fans and their ductwork are tested for their proper operation and examined where visible. Shower pans are visually checked for leakage, but leaks often do not show except when the shower is in actual use. Determining whether shower pans, tub/shower surrounds are watertight is beyond the scope of this inspection. It is very important to maintain all grout and caulking in the bath areas. Very minor imperfections can allow water to get into the wall or floor areas and cause damage. Proper ongoing maintenance will be requir ed in the future. |
| | Bathroom Location Location: Main Floor |
| Toilets Condition: Satisfactory |
| Ventilation Condition: Satisfactory Fan Vents To: Outside |
| Shower Walls Condition: Satisfactory Type: Ceramic Tile |
| Floor Condition: Satisfactory Type: Vinyl (Linoleum) |
| Receptacles Condition: Satisfactory Type: GFCI
Problems: -There are receptacles within reaching distance of the bathtub that should be moved. |
| Moisture & Mildew Condition: Satisfactory Type: None |
| Sinks Condition: Satisfactory |
|
| | | | Bathroom Location Location: Second Floor |
| Toilets Condition: Satisfactory |
| Ventilation Condition: Satisfactory Fan Vents To: Outside |
| Bathtub Condition: Satisfactory Type: Built-In
Problems: -The seal is caulked improperly. -The hot-cold controls are aligned incorrectly.
Comments: The tub may be caulked to properly seal the tile to tub areas.
The faucet control does not work properly in the tub. The cartridge needs to be changed and adjusted properly. The water turnoffs for the tub are accessable from the back wall access panel. |
| Shower Walls Condition: Satisfactory Type: Ceramic Tile
Problems: -The shower walls were uncaulked. |
| Floor Condition: Satisfactory Type: Vinyl (Linoleum) |
| Receptacles Condition: Needs Maintenance Type: GFCI
Problems: -There are receptacles within reaching distance of the bathtub that should be moved.
Comments: There are two GFCI outlets above the sink area. The receptacles on the right controls the left GFCI and the shower lights. The shower lights are properly wired, but the left GFCI may be rewired to work on its own. |
| Moisture & Mildew Condition: Satisfactory Type: None |
| Sinks Condition: Needs Maintenance
Comments: The sink is not anchored to the wall properly. Caulking is required. |
|
| | Inspection of standalone refrigerators, freezers and built-in icemakers are outside the scope of the inspection. No opinion is offered as to the adequacy of dishwasher operation. Ovens, self or continuous cleaning operations, cooking functions, clocks, timing devices, lights and thermostat accuracy are not tested during this inspection. Appliances are not moved during the inspection to inspect below or behind them. Portable dishwashers are not inspected, as they require connection to facilitate testing and are sometimes not left with the home. |
| Cabinets Condition: Satisfactory
Comments: New cabinets have properly installed. |
| Counters Condition: Satisfactory Counter Tops: Laminate
Comments: A center section has been pieced in. This may require a new countertop. However, the countertop still functions properly. |
| Dishwasher Condition: Satisfactory Operational: Operating Make: Kitchen Aide Model: Heavy duty
Comments: Includes water and ice dispenser |
| Disposal Condition: Satisfactory Operational: Operating Make: GE Model: 1/2 H |
| Flooring Condition: Satisfactory Type: Linoleum |
| Moisture and Mildew Condition: Satisfactory Degree of Damage: None |
| Range/Oven Condition: Satisfactory Fuel Type: Gas Operational: Operating Make: GE Model: Self Ignite |
| Receptacles Condition: Satisfactory Type: GFCI
Problems: -There are non-GFCI receptacles in the kitchen. |
| Refrigerator Condition: Satisfactory Operational: Operating Make: Kitchen Aide Model: Sise by Side
Problems: *The refrigerator was not inspected for signs of leakage. |
| Sink Condition: Satisfactory |
| Ventilation Condition: Satisfactory Fan Vents To: Exterior |
|
| | Many of the building's structural elements and portions of its mechanical systems are visible inside the Crawlspace. These include the foundation, portions of the structural framing, distribution systems for electricity, plumbing, and heating. Each accessible and visible component and system was examined for proper function, excessive wear or abnormal deterioration and general state of repair. It is not unusual to find occasional moisture and dampness in the Crawl Spaces and we advise annual inspections of this area. Significant or frequent water accumulation can affect the structures foundation and support system and would indicate the need for further evaluation by professional drainage contractor. We advise to monitor your Crawlspace during the rainy season. |
| Description Type: Full Access Location: Stairs |
| Foundation Condition: Satisfactory Type: Concrete
Comments: No major stress cracks were observed. |
| Stairs Condition: Satisfactory
Problems: -The stairs are missing a railing. |
| Floor Condition: Satisfactory Floor Type: Concrete |
| Walls Condition: Satisfactory Wall Type: Closed |
| Floor Drain Condition: Satisfactory Visibility: Visible |
| Ceiling Condition: Satisfactory Ceiling Type: Closed
Problems: *The ceiling was not inspected for cracks or loose sections. *The ceiling was not inspected for water damage. *The ceiling was not inspected for asbestos content.
Comments: Furnace room and work room have open ceilings. Joist show no damage. |
| Dampness Condition: Satisfactory Degree of Damage: None |
|
| | Our examination of the heating system includes a visual examination of the exposed and accessible heating equipment, thermostat, safety controls, venting and the means of air distribution. Our inspection of the heating system includes activating the heating system via the thermostat and a visual examination of the accessible components listed below. These items are examined for proper function, excessive or unusual wear and general state of repair. Heat exchangers are inaccessible by design, and are not part of the ASHI standards of practice. They must be completely removed from the furnace to be fully evaluated. Our inspection does not include disassembly of the furnace. The inspector cannot light pilot lights due to the liability. The inspector does not test safety devices. To obtain maximum efficiency and reliability from your heating system, we recommend annual servicing and inspections by a qualified heating specialist. Determining the condition of oil tanks, whether exposed or buried, is beyond the scope of this inspection. Leaking oil tanks represent an environmental hazard, which is sometimes a costly condition to address. |
| Heating System Condition: Satisfactory Type: Forced Air Fuel: Natural Gas Age: 2 years Capacity: BTU's Heat System Location: Basement Thermostat Location: Main floor living room |
| Fuel Source Condition: Satisfactory Fuel Type: Natural Gas Fuel Supply: Public Gas Status: Turned On |
| Heat Exchanger Condition: Satisfactory Status: Not Tested Visibility: Visible |
| Heat Distribution Condition: Satisfactory Type: Ductwork Pipes: Located in: Each Room |
| Unit Venting Condition: Satisfactory
Problems: -The heating system draws in air from inside the house. |
| Air Filters Condition: Satisfactory Filter Type: Electrostatic
Comments: Check with owner for manuals and required maintenance. |
| Gas Furnace Condition: Satisfactory |
|
| | This is a visual inspection limited in scope by (but not restricted to) the following conditions: - Window and/or wall mounted air conditioning units are not inspected. - The cooling supply adequacy or distribution balance are not inspected. - Pressure tests on coolant systems are not within the scope of this inspection; therefore no representation is made regarding coolant charge or line integrity. - Judgment of system efficiency or capacity is not within the scope of this inspection. - Cooling systems are not dismantled in any way. Secured access covers are not removed. - The interior components of evaporators, condensers and heat pumps are not viewed. - The interior conditions of cooling components are not evaluated. - The presence of leaking refrigerant lines, heat pump oil, etc., is outside the scope of this inspection. Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. |
| Air Conditioning Unit Condition: Satisfactory Status: Tested Age: 2 years Capacity: 60 Location: South side exterior Last Service Date: |
| Air Conditioning Type Condition: Satisfactory Type: Central Air Fuel: Turned On |
| Electrical Disconnect Condition: Satisfactory Location: Next to Condenser unit |
| Air Distribution Condition: Satisfactory Type: Ductwork Located in: Each Room |
|
| | The Garage is inspected as best as possible, but can be limited due to parked cars or personal stored items. Due to this area be cluttered or areas being inaccessible, it is common for sections that cannot not be fully inspected or items identified during our limited inspection. We suggest that a walk-through be performed once the home is vacant. If this is a new construction inspection or vacant home this area will be inspected thoroughly. Determining the heat resistance rating of firewalls and doors is beyond the scope of this inspection. Flammable materials should not be stored within the Garage area if possible.
| | Garage Description Condition: Satisfactory Type: Separate
Comments: 2 car Detached garage |
| Door Opener Condition: Satisfactory
Comments: There was no operating control inside garage for manual operation. |
| Flooring Condition: Satisfactory Floor Type: Concrete |
| Moisture & Mildew Condition: Satisfactory Type: Some Condensation
Comments: Some condensation was observed on roof sheathing. Prior to the last roofing of the garage, press board was applied as roof sheathing. Press board absorbs moisture over time. Plywood or OSB should be used.
A new roof should be scheduled within five years. |
| Receptacles Condition: Satisfactory Type: Non-GFCI
Problems: -There are Non-GFCI receptacles in the garage.
Comments: There are many receptacles throughout the garage. At least one outlet has reverse polarity. |
| Vehicle Doors Condition: Satisfactory Status: Tested |
|